Complete 2 system a/c repair and preventative maintenance check. Replaced filters and chemically clean clogged outdoor system. found both evaporator coil rusted and main floor coil is leaking Freon at the indoor coil. Found both supply box with mold, needs a UV light system to kill and prevent mold from reproducing. Found both systems low on freon, both ac compressor draws high amperage. Found both main electrical switch for compressor burnt/pitted. Found upstair power disconnect melted do to high amp draw of the compressor. Found both furnaces with worn ignition and flame sensor. Both indoor system has no water safety devices. Found upstair furnace with gas connection not to code. Will have a manager come out to evaluate system. Will give an estimate for repairs and part replacement. Both Ac system will struggle to cool