Vu T.

Vu T.


Job Checkin

Complete 2 system furnace repair and preventative maintenance check. Change both filters 16x25x1. Check safety and operations. Find upstairs heating 3-year-old operating within manufacturer spec. No concern at this time. Find downstairs heating system 16-year-old operating with worn ignition, weak flame sensor and overheating resistor on the control board and system very dirty.