5322 Palmero Ct
Buford, GA 30518
(770) 203-1600

Job Locations
for duluth, ga


Map of Duluth GA
Mark S.

Mark S.


Job Checkin

Complete 2 system a/c repair and preventative maintenance check. checked electrical, mechanical components, dusted electrical cabinets, cleared drain line, changed filter to main floor and basement. Found upstairs unit to have dirty 5 inch filter recommend to replace. Found dirty blower wheel recommend to pull and clean. Found dirty evaporator coil recommend to clean it is very corroded. Recommend adding back up water safety to upstairs unit. Found main floor system with dirty blower wheel recommend to pull and clean. Found upstairs system low on refrigerant recommend to perform leak search. Found main floor system low on refrigerant recommend to perform leak search. Leak tested upstairs found leak in evaporator coil system is from 2006 and is r22. Will need to schedule comfort advisor to come out and talk about replacement/update. Leak tested main floor system found no leak at this time added 2 pounds refrigerant system is operating and cooling at this time.