5322 Palmero Ct
Buford, GA 30518
(770) 203-1600

Job Locations
for duluth, ga


Map of Duluth GA
Vu T.

Vu T.


Job Checkin

Complete 2 heating maintenance in Duluth. Check and find d 6 year old Lennox furnace operating with minor ware on flame sensor and need to keep check. Need to replace 16x25x4 filter. System operating with in manufacturer spec. Find older Ruud gas furnace operating with worn gas valve, and weak thermal couple. Find heat exchanger rusted. Flue pipe not up out code and missing water protection.