5322 Palmero Ct
Buford, GA 30518
(770) 203-1600

Job Locations
for flowery branch, ga


Map of Flowery Branch GA
Reece W.

Reece W.


Job Checkin

Complete 2 system a/c repair check. Found system with bad capacitor causing outdoor fan motor to not turn on. Also found weak blower capacitor. System only has one form of water safety, recommend in line water protection to protect furnace from water damage and act as a backup to primary water safety. Recommend surge protection to protect system from power surges. Replaced both capacitors, installed hard start kit and installed secondary water safety. System is cooling at this time. Signed customer up for two system maintenance plan, will return to do maintenance.