1 system a/c repair and tune-up. Replaced filter, cleared drain and sprayed a/c coil. Found rusty coil and mold inside air handler. Needs a UV light system to kill bacteria and mold. Found outdoor compressor loud noise on startup. Found burnt/pitted main switch. Recommend to replace burnt main switch and add a compressor saver to help system on startup.