5322 Palmero Ct
Buford, GA 30518
(770) 203-1600

Job Locations
for johns creek, ga


Map of Johns Creek GA
Reece W.

Reece W.


Job Checkin

3 heating system preventative maintenance check complete. Changed upstairs and guest house filters. Found guest room system shutting off on low-pressure lockout due to it being void of refrigerant. Having no refrigerant in the system indicates a major leak. Recommend upgrading system. Found main level/ upstairs furnace with very high, unsafe levels of carbon monoxide, recommend recalibration to reduce co levels down to safe levels. The furnace also has a worn ignition system and weak blower motor controller. Basement system is also going off on low pressure due to it being void of refrigerant. Replaced blower motor controller and ignition system, and recalibrated CO levels from 133 ppm down to 22 ppm.