Job Checkin

Complete 3 a/c preventative maintenance check. Found main system operating with pitted and burnt main electrical switch, weak capacitor and missing additional water protection for the drain line. Find basement new Trane system operating normally. Find guess room system operating normally. Suggest customer repair main system but customer denied repair suggestion at this time. All 3 system cooling at his time but the main system is not reliable.Heating and cooling maintenance complete which will help lower cooling cost for this residential customer. Cooling system is now ready for spring and summer weather.