5322 Palmero Ct
Buford, GA 30518
(770) 203-1600

Job Locations
for oakwood, ga


Map of Oakwood GA
Jon F.

Jon F.


Job Checkin

Complete 2 system furnace repair and preventative maintenance check. Found upstairs with a standard one inch filter. Blower wheel is clean. Flex gas line going into furnace which is not code and single wall flu which is also not code. System does have UV air purifier that is running good as well as 2 forms of water safety which both work. Flame sensor and igniter are clean and working. System is heating. Attic stair case has no attic tent meaning the only thing dividing the attic and living space is a thin price of plywood which allows heat to escape very easily. Recommend attic tent for better insulation which can lower bills. Downstairs needs secondary water safety switch as well as UV purifier to treat whole house. Also downstairs has standard 1 inch filter and out of code flu and gas line. Installed compressor saver that was recommended at last visit. Systems are heating.