Gas leak in Oakwood Georgia. Found gas line with a leak took videos and pictures also system has been red tagged by the gas company. Flex hose is running into the furnace which is a safety issue. Neither the furnace or water heater has a sediment trap . Need to hard pipe the gas line going into the furnace and water heater and add sediment traps to both . Today we’re fixing the gas line . Put a new shut off valve on the gas line . Added two sediment traps . Installed hard pipe in the furnace. Fixed gas line . System is now operating and not leaking gas into the home .