6657 Corporation Pkwy #250
Fort Worth, TX 76126
817-994-4194

Local Reviews
for saginaw, tx

Rated 5.0 out of 5 stars based on 7 customer reviews

Great customer service!


Response from Comfort Masters Heating & Air Conditioning:

Hi Jackie. Thank you for your great review. We appreciate you and your business!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great customer service

Had a great experience with Josh. Very personable, very knowledgeable and informative, and very helpful all around! Came out quickly even though it’s a holiday weekend.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Integrity & Trust

Whenever Geno is on-site I’m confident he will find the real problem and not just swap parts. Very happy with their service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

On Time, Wore Mask

Bobby was great.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Polite, Knowledgeable service, amazing price!

Bobby Aderholt was absolutely amazing, he came to assess our situation and was polite and respectful. He gave us the step by step on our issue and sold us on the platinum package so they can keep up with our service. He quoted up step by step on the pricing and started with our concerns!!! He was the absolute best!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service!

Bobby came out and did a QC on our new HVAC system. He was polite and very knowledgeable. I would definitely recommend!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent

Excellent. Very prompt and friendly. Very good service thank you

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for saginaw, tx

Ruben N.

Ruben N. Job Checkin

Checked entire system for homeowner and gave options on repairs.


Joshua M.

Joshua M. Job Checkin

Performed cooling maintenance and found compressor windings shorting and trippin breaker


Joshua M.

Joshua M. Job Checkin

Perform cooling diagnostic, found compressor wires shorted and tripping breaker


Jacob H.

Jacob H. Job Checkin

Performed quality check on new Amana straight AC system.


Mathew B.

Mathew B. Job Checkin

Performed quality check on new Amana system


Mathew B.

Mathew B. Job Checkin

Found leak in carrier evaporator coil


Geno G.

Geno G. Job Checkin

02-08-21, performed the fall maintenance on one Amana heat pump variable speed system. Had to adjust the compressor lockout from 0° to 25°. Found outdoor system frozen and needed to be thawed out. Checked defrost timing board to verify board does work. Also checked 10K W heat kit functioning properly. See attached sheet For details. Return system back to normal operation. Thank you


Geno G.

Geno G. Job Checkin

12-08-2020, Performed fall maintenance on one of their rental properties. Found temperature rise reading low so I increased the gas pressure to achieve a higher temperature rise so the house would heat Up quicker. Check the rest of the system and found all major components functioning normal, safeties are working, gas line is tight, flue pipe is secure, unit is sealed properly. No issues at this time. Thank you for giving us the opportunity to serve you.


Mathew B.

Mathew B. Job Checkin

Performed system maintenance on a Amana heat pump


Bobby A.

Bobby A. Job Checkin

Came out due to high humidity in home, upon arrival spoke with client to find out in her own words what was going on, after discussion performed service checklist by checking motors, voltages, amperages, drain line, filter, delta t, capacitors, contactor, refrigerant charge, condenser coil cleanliness, etc., etc.. while performing checklist found that dual capacitor for outdoor unit was reading 43/4.4 of 50/7.5, this is well below manufacturer specifications and was recommended to replace, also found that the condenser coil was pretty dirty, spoke with client about moving system to maintenance and client approved, washed out condenser coil thoroughly with water hose, as of today the only thing that I was able to find that would contribute to high humidity in home would be the dirty condenser coil. System is operating per manufacturer specifications. Spoke with client about our maintenance membership programs and client has chosen to decline at this time.


Bobby A.

Bobby A. Job Checkin

Came out due to 2 bedrooms not keeping up in the heat of the day, upon arrival performed checklist by checking duct work, motors, voltages, amperages, drain lines, float switch, delta t, capacitors, contactor, condenser coil cleanliness. While performing checklist found that system was double filtered, one in the filter grille and one up at the unit, took filter out of filter grille and let client know what happens when it is double filtered like that, also found that the 2 rooms in question normally left their doors closed, let client know that with the doors closed there is no way for the system to circulate the ambient heat out of the room therefore without air circulation those rooms would not be able to cool. Also found that 9” duct that feeds those 2 rooms is at the beginning of the plenum so if by removing that one filter and keeping those doors open during the day that we would need to move into adding manual dampers into the system and then performing an air balance to force m


Bobby A.

Bobby A. Job Checkin

Came out to perform Quality Check on clients brand new 18 seer 2 stage heat pump system, upon arrival performed quality check by checking motors, voltages, amperages, wiring, electrical connections, delta t, refrigerant charge, breakers, seal of equipment, overall cleanliness of install, etc., etc.. while performing QC found that the TXV did need to be adjusted, adjusted TXV to the proper charge. System is now operating at 9.5° sub cooling and 14.8° superheat with a delta T of 19° with the return air temperature at 71° in the supply air temperature at 52°. System is operating per manufacturers specifications.


Bobby A.

Bobby A. Job Checkin

Came out for a warranty no cool, upon arrival turned the system on in the cool mode, upon arrival found that unit started right up and began cooling, upon arrival to air handler found that the float switch though not engaged has water in it, used a pitcher of water to fill up primary drain line and the primary drain line was clogged, tried to perform drain line clear out with pressurized nitrogen down and into sink with 75 psi of nitrogen, than tried with 100 psi and was not able to clear drain line, took a trash bag and taped it over primary drain line at air handler, then went to sink where it drains to, cut drain line and blew it back to trash back and felt zero resistance, pulled apart p trap u dear sink and found that the Tee under sink was completely clogged, took it completely apart and washed out Tee and 3/4 primary drain line that hooked to Tee with water hose and then took towel and clean off pipe from sink that slide down into Tee, added bleach to primary drain line to clean


James W.

James W. Job Checkin

J Replace ends on compressor common wire. Install hard start kit. Replace contactor. 1 year part and labor warranty on repairs.


Stephen  M.

Stephen M. Job Checkin

Working on the Air Conditioning