John did a thorough review and presented his findings clearly and was patient with my questions
Very responsive when my furnace went out in sub zero temps. Very good reminder texts/emails/phone calls etc and dressed and acted like a pro. I will call them next time for sure
John is a experienced and informative technician. He went over all that my AC needs and gave options for pricing.
Wesley did a great job and took the time to explain all of the options for service to me.
Helped put door on correctly and install new filter.
Furnace precision tune up; clean and tune up furnace; clean burners, test ignition components, adjust gas level, test safety circuit, check indoor motors, checked all electrical components, tested indoor air flow, checked heating temperatures, and tested overall furnace operation. Recommended a blower wheel cleaning, electronic air cleaner and surge protector. All recommendations were declined at this time.
AC precision tune up. Clean and tune up AC; cleaned condenser coil, checked all outdoor electrical components, tested indoor air flow, checked refrigerant levels, and tested overall AC operation. Recommended blower wheel cleaning
Two furnace precision tune up; clean and tune up furnace; clean burners, test ignition components, adjust gas level, test safety circuit, check indoor motors, checked all electrical components, tested indoor air flow, checked heating temperatures, and tested overall furnace operations. Both blower wheels are in need of a cleaning. Both blower starters are failing. Flame safety is failing on garage furnace. Systems are up in age, replacement may be in future.
Furnace tripped upon arrival. Reset power to test operation. Diagnosed a failed flame safety. Replaced failed part with new. Furnace is now heating correctly. Did also find blower starter failing. Unit is surpassing its lifespan. Replacement is encouraged. Jonathan will come out 2-8-22 at noon to quote replacement.
Performed Furnace precision tune up; clean and tune up furnace; clean burners, test ignition components, adjust gas level, test safety circuit, check indoor motors, checked all electrical components, tested indoor air flow, checked heating temperatures, and tested overall furnace operation. Recommend blower wheel cleaning to ensure that blower fan is pushing maximum airflow through ductwork to avoid any issues revolving around airflow. Also performed a Humidifier precision tune up and cleaning. Remove current water pad, clean off pad housing and water distributor. Clean out humidifier box. Clear out drain line. Replace with new water pad. Test operation
Found all registers closed on bedroom zone. Found one pipe that was connected to living room zone that is constantly getting air which is fooling the thermostat that that room is cool. Will need to go back and correct piping that is fooling the thermostat
Customer stated that the A/C causes high electrical bills. I confirmed the refrigerant levels. Levels are where they should be. Outside motor booster and starter are in poor shape. Unit could use a tune up. System is over 20 years old. It’s not as efficient as it was when brand new. System is at the end of its life. Jacob will come out 8-4-21 at 12:15pm to quote replacement .
I performed annual maintenance on a Bryant air conditioner
I replaced a failed transformer on an Amana furnace
I performed annual maintenance on a Daikin air conditioner and a Ruud air conditioner
I diagnosed a failed pressure safety switch on a Lennox air conditioner
I diagnosed a failed control board on a Carrier furnace