Performed AC maintenance on a 2007 Air temp condenser. Cooling temperature split is 20 degrees. filter is very dirty. Condensate lines are clear. Condensate pump is in good working condition. Systems return is very small causing restriction. Duct runs have been replaced recently. Indoor blower is very dirty. Blower motor is slightly leaking oil. Battery for the blower is in range .Outdoor unit was deep cleaned. Fan motor is leaking oil. Battery cap is out of range on both terminals causing the fan motor seal to break. Compressor start and run amps were recorded. Refrigerant levels were off. System was running st end of appointment. Homeowner knows the condition of his equipment wants to hold off on repairs due to a long list of other home repairs.