Performed Fau maint on 2007 furnace. Cycled furnace for heat. Verified proper heating sequence of operations. Temperature rise across heat exchanger is within range. Indoor blower motor amps are slightly high, and there is a lot of oil loss present on the fan blades coming from the indoor motor. Recommend replacing indoor blower motor. Secondary motor control is in range. Tested and verified that heating components are working accordingly. Wiped down burner compartment. Wiped down exterior of unit. Homeowner fully understands the age of all of his equipment. Recommend replacing indoor blower motor to avoid any issues with heating or cooling. System is fully operational upon departure. Aftermarket Blower motor -$709.00 OEM Blower Motor- $1,009.00