Performed maintenance on 2 13 year old systems. Homeowners were not available, met with homeowners brother. Cycled systems for cooling. Checked outdoor unit electrical and system components. Pulled condenser fan motors on both units and thoroughly washed wash out and vacuumed condenser coil inside and out. Condensers were super dirty. Performed thorough evaluation of systems, concerns are as follows 1. Compressors on both units are starting up hard 2. Condenser fan motors on both systems are over amping 3. Condenser fan motors on both systems have leaked out a significant amount of oil 4. Condenser coils are starting to corrode 5. Indoor blower wheels are dirty 6. Indoor blower motors are leaking oil as well There was no homeowner available to go over recommendations. Writing up invoice and emailing it over. Cycled systems, systems are fully operational upon departure.