41638 Eastman Dr. Suite B
Murrieta, CA 92562
(888) 659-2665

Job Locations
for murrieta, ca


Map of Murrieta CA
Jimmy P.

Jimmy P.


Job Checkin

Performed diagnostic on blank thermostat. Upon my diagnostic customer stated that thermostat has been blank since the summer time. Further investigation shows that the three amp fuse was blown on the circuitboard. Replaced fuse in system is fully operational in heating and cooling although could not replicate the fuse popping like it did in the summer. Advised customer that this could be caused by multiple different things from all the way out at the condenser contactor coil, the circuitboard or thermostat wires shorting. Did a further inspection and noticed that the indoor blower is leaking oil along with a 3.5 weak capacitor. If this indoor blower fails this will no longer work in heating or cooling mode. Advised due to the age of the system It is unpredictable whether or not the fuse may pop again or another component will fail soon due to the condition overall. Signed customer up On energy savings agreement to perform a standard Maintenance on the AC and heating system. Findings-