Performed heating maintenance on a 2013 Carrier gas furnace. Customer reports good working Equipment in heat mode this year. System is zoned for upstairs and downstairs. Heating temperature split is 43. Sensors and switches were cleaned and tested. Gas valve was tested. Combustion blower is ok. Primary blower is amping high. The oil from the blower motor is all leaked out over the blower compartment. These are 2 signs of failure for the blower motor which moves the air for heating as well as cooling and fan mode. Duct runs are sealed. Zoning system was tested. Indoor equipment is not protected. Homeowners are aware of the condition. Husband wants a day to research blower motors and think about it. System is operational.