41638 Eastman Dr. Suite B
Murrieta, CA 92562
(888) 659-2665

Job Locations
for temecula, ca


Map of Temecula CA
Tyler H.

Tyler H.


Job Checkin

Upon arrival found the system to be in lockout, the limit switch was activated. Tested the limit switches and found no issues. Tested system operation and found the high limit switch was going off after the motor started running. Tested amp draw on inducer motor and found no issues. It should be noted that the inducer motor is making extremely loud noises during operation. Sounds like the internal rotor is out of balance. Tested the battery cap and found it to be over 50% out of range. The filter is also extremely dirty. Washed the filter. Replaced the cap and tested system operation. The system finally stayed on. Check temp splits and mechanical operation and found no issues. System is operational upon departure.