41638 Eastman Dr. Suite B
Murrieta, CA 92562
(888) 659-2665

Job Locations
for temecula, ca


Map of Temecula CA
Jimmy G.

Jimmy G.


Job Checkin

Arrived on site to perform combo tune up on a 2020 lennox unit. Condenser located back yard and furnace and Evaporator coils located in laundry room closet. Client stated no issues and everything is working good. Washed condenser inside and out. Checked electrical compartment and components. Both primary and secondary motor controls are both good and in range. Start up amps are good on compressor. Run amps are good and in range. Fan motor is good. System pressure is good and cooling at 19 degrees. No protection on unit. Inspected indoor unit. Filter was extremely clogged and restricting unit of air flow. Needs new one. Blower assembly a slight dusty due to clogged filter. Motor is good and in range. Evaporator coil is good but advised a clogged and dirty filter could clog up drain line if dirt keeps getting into system so filter needs to be replaced sooner if needed. System is cooling at 19 degrees. All safety switches are operational. No protection on unit. Recommend adding surge pro