41638 Eastman Dr. Suite B
Murrieta, CA 92562
(888) 659-2665

Job Locations
for temecula, ca


Map of Temecula CA
Jimmy G.

Jimmy G.


Job Checkin

Arrived on site to perform spring tune on a 2004 comfort maker system. Condenser located in back yard. Furnace and evaporator coil located in attic. Client stated no issues and that he know system is old but is still operational and cooling. Washed condenser inside and out. Condenser was rebuilt last time out. Primary, secondary and fan motors are all good. Unit also has a compressor booster kit as well. Compressor start ups are low and good. Run amps is still working really hard and he is aware as it’s pulling 22 amps and max rated at 27. Lennox n a hot summer day Thai compressor can over work and even fail. Pressure are stable and cooling home at 20 degrees. No protection on unit. Inspected indoor unit. Filter is dirty but client will replace him self. Blower assembly is dirty. Motor is good. Secondary motor control is good as well. Evaporator dose have debris from past years of dirt entering system. Drain do not have any over flow safety switches. Would recommend adding one to p