Jimmy G.

Jimmy G.


Job Checkin

Arrived on site to perform spring tune up on a 2 20 year old unit. Both condenser are located in back yard. Furnace located in attic. Client stated no issue and is cooling. Washed condenser coil inside and out. Checked both electrical compartment. Checked both primary Staters and are okay. Both secondary motor controls are good and have been replaced in past. Fan motor are good but are working hard as over all conditions of units are old and using a lot of power. Both fan motor are in range but have a bit of oil. Checked start up and run amps both start up amps on compare good as they got booster kit added on. Found run amps to be high as both are pulling 16 amps at 82 degrees outside. Max is 21. Advised at 100 degrees outside those number can go up and compressor is pulling alot of power. Advised units are on borrowed time. Both units hold R-22 and found the smaller unit to be low and not cooling as low side is at 40 and the other unit is hold a good charge as low use is at 67 and coo