Jimmy G.

Jimmy G.


Job Checkin

Arrived at customers house to preform a heating tuneup. We first cycled system on and everything turned on and was operational. Next we checked the total bower amps and inducer amp draw, both were within limits and testing good. Next we checked static pressure and took a temp rise, both static pressure and temp rise were both good and within their desired range. Next we checked all safety and high limit switches, the switches were testing good and were function and operational when tested. Drain lines are clear. Cleaned flame sensor and igniter is good. We changed filter 20x25x5 as the filter was lookin dirty and needed to be replaced. Over all the while we were there the system was testing good and was operational. Surge protection is good and active. Phenomenal air is good and cleaning. Cycled system to ensure system operating. System is operational upon departure.