Performed diagnostic on 34 year old carrier system. System is not cooling. Homeowner states that his indoor fan is not kicking on and not blowing air, his outdoor unit is turning on normally. Cycled system for cooling. Outdoor unit kicks on, indoor unit is unresponsive. Checked indoor unit electrical and system components. System is recieving proper high voltage power as well as low voltage command, but fan is not turning on. After thorough diagnostic, found that fan command is getting lost at the circuit board. Circuit board is recieving the command from thermostat, but it is not sending it out to the fan motor. Circuit board would have to be replaced. Indoor blower motor is leaking oil and back housing is completely covered in dirt and dust. Blower wheel is also extremely dirty and has signs of oil loss. System is extremely old and in poor condition. Went through findings and recommendations with homeowner. Went over condition of System and average life expectancy of a system. Homeow