41638 Eastman Dr. Suite B
Murrieta, CA 92562
(888) 659-2665

Job Locations
for vista, ca


Map of Vista CA
Luke H.

Luke H.


Job Checkin

Upon arrival found system thermostat disconnected from wall. Reconnected thermostat and tested and verified correct operation of system. Checked the system and everything checked out good. Return is very restrictive and filter was really dirty before it was replaced yesterday. Flame sensor was also extremely dirty and needed to be cleaned. Recommended signing up for ESA to make sure system can last as long as possible. Also recommend upgrading filter and opening up return