Job Checkin

Performed AC diagnostic on 2010 Goodman condenser. Prior to visit Ben had stated that the system had already had a small leak occurring within the evaporator coil and that was diagnosed by the previous company I did not have access into the house And was not able to verify Indoor System, filter, and temperature split. And stated that it is about 73° inside the house and added about 4 pounds of R410a refrigerant which still left it quite low due to high amount of refrigerant missing. Suction was at 47 psi and high pressure was at 157psi before charging it. Ben had mentioned the last time It was charged up was about a year ago. I did inform Ben That this is a Band-Aid for the system and I am not sure how long this refrigerant charge will hold until the next time he needs more due to the size of the leak potentially. He’s trying to get another summer out of it will give us a call if anything happens. Upon departure system is cooling.