Job Checkin

Arrived on site to perform Ac maintenance on a 2018 Lennox system. Condenser located in back yard p. Furnace and Evaporator coil located in hall closet. Client stated no issues. Cycled cooling to ensure system operating. Found fled ducting used. Filter was dirty. Client did supply her own filter and advised due to the are she lives in she may need to replace more frequently if needed. Checked electrical wiring, connections, circuit board, and components all good. Blower wheel is slightly dusty due to lack of filter change out. Motor is good. Free of oil. Evaporator coil is good at this time. Condensate float switch and all other safety switches are operational. Temperature split was in range of 23 degrees and cooling. Cycled system. Washed condenser coil out side as it was really dirty and filled with leave due to tree above unit. Checked electrical compartment and components. All good. Primary and secondary controls are in range. Checked fan blade, searing , and motor. All good. Amp d