Arrived on site to perform combo Tune up on a 2019 lennox unit. Client stated no issues just wanted to replace filter cause client has allergies. Furnace and Evaporator coil located in attic. Cycled cooling. Washed condenser inside and out. Checked electrical and primary and secondary motor controls are both good. Start and run amps are all good and in range. Fan motor is good and in range. System pressure are good. No protection on unit. Inspected indoor unit. Filter was dirty and clogged and client wanted to replace. Blower assembly is good. Motor is good and in range of amp draws. Inducer motor is good and in range. Evaporator coil is good at this time. Drain lines are good at this time System is cooling at 21 degrees and heating at 48 degrees. All other safety switches are operational. No protection on unit recommend adding a surge protector on unit to protect if from getting damaged from electrical surges and power outages that can damage or even short out systems and components