Dave moved and installed a new thermostat for us. He was timely in contacting me after I sent a request for service online. He is very knowledgeable, provided excellent service and gave good suggestions to maximize the effeciency of our hest pump.
Furnace service call on a 80% temp star gas furnace found a dirty flame sensor and a bad hot surface igniter
Performed air-conditioning tuneup on a Goodman unit checks out good except the dual run capacitor was bad replaced and clean coil air-conditioners ready for summer
Installed a new programmable Wi-Fi thermostat cycled heat pump all working
Provide a quote to move thermostat from second floor to first floor customer agreed to job and I will perform it Thursday
Arrive for a no heat service call on a Westinghouse Air handler found control board burned up replace the control board transformer blower motor cycle unit heating properly
Replaced heat exchanger on a Goodman furnace also replace burners waiting on gas company for gas service to light
Arrive for a no heat call on a Ducane furnace found a dirty flame sensor and a bad blower capacitor furnace is he heating well after repairs and
Performed a no heat service call on a Lennox furnace customer stated that unit would not fire unit was working correctly customer was not allowing enough time for system to turn on
Quoted new Comfortmaker 92% efficient furnace
Arrived for no cooling call on a Singer ac system. Found unit out of freon. Advised customer of options Recharged at customers request system running now
service call on a Bryant Gas furnace. Found inducer motor lock rotor amp. replaceed inducer assembly. unit working now and heating
arrived on an emergency no heat call on a gas furnace. found blower capacitor bad and not allowing blower to come on. replaced capacitor and furnace is now running
Ran service call on gas hot water tank. The pilot was not staying on. Cleaned thermocouple and unit is working now.