Sewage backing up into two rooms. Turned off water to toilet. Removed water from tank. Removed existing China caps. Removed existing closet bolt nuts. Removed existing water supply. Pulled toilet. Removed existing closet bolts. Removed existing wax ring. Ran camera down drain and found stoppage at approximately 10 feet. Ran Spartan 300 to approximately 15 feet. Pulled snake and found what appeared to be wet wipes on the head of the snake. Ran camera down drain to 25 and found no signs of stoppage. Installed new wax ring. Installed new closet bolts. Reset toilet. Installed new water supply. Installed new closet bolt nuts. Installed new China caps. Tested toilet by flushing 15 times. No signs of stoppage, slow draining or leaks found at this time. Ran 4 fixtures for 10 minutes. No signs of stoppage found at this time. Applied caulking to base of toilet. CPI plumbing and heating does not warranty or guarantee any drain cleaning. Thank you for choosing CPI plumbing and heating!