Job Checkin

Performed inspection on home. Tested all lavatory faucets. Dye Tested all toilets. Inspected all visible drain piping. Water pressure to home was at 70psi. Crawlspace showed no signs of leaks. Will return to perform work as proposed. 10/26 Turned water on to home. Drained system, Replacement all remaining multi turn emergency shut offs with quarter turn shut offs. Installed new water supplies to all fixtures. Removed existing lavatory faucets. Installed new two handle lavatory faucets. Flushed system of any debris by removing aerator and running faucets for 30 seconds. Load tested each Faucet 5 times. No signs of leaks. Walked through home twice to check for leaks at all new shut offs. No signs of leaks found at this time. Thank you for choosing CPI plumbing and heating!