Manny V.

Manny V.


Job Checkin

Customer called in because of high water alarm on sewage ejection pump system going off. Provided pricing to perform diagnostics on system, also per customer request provided pricing for pump replacement. Customer decided to go ahead with diagnostics. Had customer shut power down to the pump. Shut isolation valve down. Removed existing union. Pullled pump. Had customer return power to system. Verified impeller is working correctly. Verified check valve was moving freely. Note- when removing pump found debris floating in the water after pump was fully removed, removed and re-installed high water alarm float. Re-installed pump and union. Returned power to system. Pump working as designed. Note-highly recommended customer call an electrician to re-wire system. If any further work is performed unable to warranty work or repairs due to existing electrical connections.