1900 Railroad Ave
Mt Vernon, WA , WA 98273
360-219-9468

Job Locations
for concrete, wa


Map of Concrete WA
Coady P.

Coady P.


Job Checkin

Customer reported that they had two leaks on their water supply piping. Water was off to home upon arrival. A new water line had been installed from park supplied yard hydrant to home and connected to Gray polybutylene supply. Leak under bathroom sink has caused water damage to cabinet. Customer is going to repair. Found another leak under water heater on gray polybutylene. Will return to install new pex plastic piping in place of old plastic piping. 5/26/21 Water was off to home upon arrival. Turned off power to water heater and drained. Drained water from existing water supply piping. Provided and installed new pex plastic supply piping to all fixtures in home, and connected to newly installed main water line in crawl space. Cut access in wall behind shower valve and connected pex as close to valve as possible. Installed new shutoffs for lav sink, kitchen sink and toilet. Connected to new piping in crawlspace. Installed new main water shutoff valve on west side of home just inside