Cut out all of the pipes connecting to the pump and to the bottom of the pressure tank Removed burnt out pump and popped expansion tank Made new connection to the poly suction line and the drive line pipe that goes back into the well Piped in a new jet well pump and 65 gallon expansion tank Pressure switch on pump is set at 30psi to turn on and 50 psi to turn off Under rear cover of pump flipped the switch on the pump from 230volts to 115volts because the power supply for the pump is only 120VOLT domestic plug Recommend having an Electrician come in and run 230 V wire to the pump this will allow the pump to work twice as hard but it’ll be more efficient because it wont have as long of run times when it’s building pressure back up to 50psi Ran through several cycles before closing up