1900 Railroad Ave
Mt Vernon, WA , WA 98273
360-219-9468

Job Locations
for oak harbor, wa


Map of Oak Harbor WA
Jon M.

Jon M.


Job Checkin

Customer stated water was shutoff to building due to water leaking from ice maker valve. No access to install ice maker box. Provided estimate to install valve and run water supply through cabinets and customer agreed to work. Turned water off to building and removed saddle valve on 1/2 inch copper line in crawlspace. Removed cold shutoff valve under kitchen sink and installed dual shutoff valve for kitchen faucet and ice maker. Routed supply Line through cabinets to reach fridge. Provided estimates to replace water heater and customer agreed to work. Turned power and water off to water heater. Drained water from tank and removed old water heater. Installed new earthquake straps and replaced shutoff valve for water heater. Installed foam pad under water heater. Installed new 50 gallon electric water heater. Turned water back on to building and filled tank verifying no leaks present. Turned power on verifying proper amp draw and incoming voltage. Insulated water piping. Thank you for