Performed annual maintenance on two 19 yr split Goodman systems. Downstairs and upstairs. Tested all parts. Contactor looks good, checked disconnect and wire connections all tight at this time. Dual capacitor 35-5 ok. Refrigerant levels for downstairs unit just above freezing. For upstairs unit in bad shape, see pictures. Line sets insulated. Upstairs unit outdoor fan making noise, and pulling high amps. Upstairs unit electrical panel not attached fully. Downstairs unit disconnect not shut fully. Washed both condensers. Black fed ducts taped not sealed. Due to age of system, would recommend repair vs replace options. Added refrigerant, r22, to system to get system above freezing point and correctly cooling.