Performed annual heating maintenance x2, split Goodman systems Downstairs system in master bedroom closet. WiFi thermostats. 14-25-1 filter. Cycled unit on. System turned on, cleaned off attic platform. Some staining on wood, keep an eye on it. Tested system parts. Hot surface ignitor 65ohms, blower capacitor 12.5@11.3. Primary control board ok. Unit has been converted to lp. Cleaned burners and flame sensor. All style coil/plenum. Black ducts taped not sealed. Some inefficiencies, due to age and shape of system as well as setup. System is working for now. Upstairs furnace WiFi thermostat, tested system. System operational. Found seal between furnace and all style coil broken. Pushed the furnace and coil as close together as possible trying to stop leakage. Found rattling noise from return side of blower compartment needs to be properly sealed. Blower capacitor 12.5@12.6, hot surface ignitor 41ohms. Control board ok for now. Unit has been converted to lp. Both units are getting up