Performed system check up Lincoln. On a 16 yr split system side yard closet. Found system with broken disconnect, see picture. For code condenser doesn’t need disconnect so close to breaker panel. Condenser Unit is too close to wall. Refrigerant pressure ok. Temp split 18-20... 80 degree air going in 60-62 degree air temp average. Register in master bedroom faces the wall not the bed, master bathroom has a floor register. Filter is in a stamp face grill not a return air filter grill. Blower is dirty blower capacitor ok. Filter use to be inside unit. Duct work to garage is uninsulated alumiflex with holes in it. Multiple holes, see pictures. Rest of ducts are hard pipe. Went thru system today to see how old system is and in what shape it’s in.