Loomis California performed AC diagnostic found compressor with tripped main breaker found electrical wiring at main breaker loose tightened electrical wiring at breaker inspected rest of system found electrical tight at service disconnect, found electrical connections tight inside of unit, performed electrical test on unit found electrical test to be showing a caution which is indicate a possible short. tested compressor independently found compressor windings causing issue in conjunction with loose electrical wiring caused the breaker to trip. Compressor issue will most likely cause compressor to burn out completely recommend replacement of system customers doing a remodel towards the end of the year will most likely have the systems replaced then. Will need to perform AC maintenances within 2 to 3 weeks per agreement with customer