— Diagnostics — - Shut power off to well and begin diagnostics - Verify voltage and amp draw to pump - Inspect pressure switch and test by forcing to engage and disengage - Verify voltage to pump — Pressure Switch — - Shut down power to existing pressure switch for removal - Remove pressure switch by cutting out housing - Disposal or switch included - Reconfigure wiring to accommodate for new pressure switch wiring requirements - Test unit by operating using power provided — 3/4 HP Pump Replacement — - Shut water down and drain system to prep for removal - Disconnect piping at unions and keep - Disconnect electrical from pump for removal then reconnect - Utilize as much of existing parts onsite as possible - Install new pump identical to existing pump at owner request - Pressure up system and verify operating properly - Install new large face gauge in place of existing small face gauge - Provide new filters for existing filter port near by