Mark P.

Mark P. Job Checkin

I performed a tune up and safety on a air conditioner unit. Upon arrival I discovered that the unit was working as intended and there wasn't anything needing repaired.

 I performed a tune up and safety on a air conditioner unit. Upon arrival I discovered that the unit was working as intended and there wasn't anything needing repaired.

Ashton H.

Ashton H. Job Checkin

I installed a Carrier 96% 60,000 BTU Gas Furnace and a Carrier 13 SEER 3 Ton Air Conditioner. System is set and customer is ready for the cooling season.

I installed a Carrier 96% 60,000 BTU Gas Furnace and a Carrier 13 SEER 3 Ton Air Conditioner. System is set and customer is ready for the cooling season.

Ashton H.

Ashton H. Job Checkin

I installed a Carrier "Infinity Series" 80% 2 Stage Variable Speed 70,000 BTU Gas Furnace and a Carrier 2 Ton Performance 16 SEER. Equipment is set and customer is ready for the cooling season.

I installed a Carrier "Infinity Series" 80% 2 Stage Variable Speed 70,000 BTU Gas Furnace and a Carrier 2 Ton Performance 16 SEER. Equipment is set and customer is ready for the cooling season.

Ashton H.

Ashton H. Job Checkin

I installed a Five Star 80% 70,000 BTU Gas Furnace with an Aprilaire 600M Humidifier. Everything is working within manufacturers specifications at this time.

I installed a Five Star 80% 70,000 BTU Gas Furnace with an Aprilaire 600M Humidifier. Everything is working within manufacturers specifications at this time.

Mark P.

Mark P. Job Checkin

I rewired humidifier control and tested. I then ensured that the heating cycle ended when system shut off. Humidifier and 2020 Carrier gas furnace both operating properly at time of departure.

I rewired humidifier control and tested. I then ensured that the heating cycle ended when system shut off. Humidifier and 2020 Carrier gas furnace both operating properly at time of departure.

Noah B.

Noah B. Job Checkin

I replaced a high limit switch on a Carrier 80% 90,000 BTU Gas Furnace

I replaced a high limit switch on a  Carrier 80% 90,000 BTU Gas Furnace

Noah B.

Noah B. Job Checkin

Found main limit sticking open. Dirty filter caused multiple overheat conditions, recommend replacing main limit. Replaced filter, now heating.

Found main limit sticking open. Dirty filter caused multiple overheat conditions, recommend replacing main limit. Replaced filter, now heating.

Ashton H.

Ashton H. Job Checkin

I installed a Carrier 96% 60,000 BTU Gas Furnace

I installed a Carrier 96% 60,000 BTU Gas Furnace

Noah B.

Noah B. Job Checkin

I am Performing our Five Star Tune-Up & Safety Check on a 2007 Bryant Gas Furnace. All readings were within manufacturer's specifications, unit operating properly at this time.

I am Performing our Five Star Tune-Up & Safety Check on a  2007 Bryant Gas Furnace.  All readings were within manufacturer's specifications, unit operating properly at this time.

Noah B.

Noah B. Job Checkin

I provided an estimate for a new Carrier 96% Variable-Speed Two-Stage Gas Furnace and a new Carrier 16 SEER Air Conditioner

I provided an estimate for a new Carrier 96% Variable-Speed Two-Stage Gas Furnace and a new Carrier 16 SEER Air Conditioner

Noah B.

Noah B. Job Checkin

I provided an estimate for a new Carrier 96% Gas Furnace a long with a new Carrier 13 SEER 3 Ton Air Conditioner

I provided an estimate for a new Carrier 96% Gas Furnace a long with a new Carrier 13 SEER 3 Ton Air Conditioner

Noah B.

Noah B. Job Checkin

I added 1 pound of Refrigerant R-22 Freon to a 2003 Carrier Air Conditioner

I added 1 pound of Refrigerant R-22 Freon to a 2003 Carrier Air Conditioner

Noah B.

Noah B. Job Checkin

Carrier AC not cooling efficiently due to humidification in the home. Request dehumidifier to be installed in the home.

Carrier AC not cooling efficiently due to humidification in the home. Request dehumidifier to be installed in the home.

Noah B.

Noah B. Job Checkin

86693


Mark P.

Mark P. Job Checkin

Installed iWave air purifier for Blacklick customer.

Installed iWave air purifier for Blacklick customer.