DELFIELD STEAM TABLE STILL NOT HEATING UP. Rewired two elements
PERFORMED PREVENTIVE MAINTANCE ON 14 PIECES OF EQUIPMENT
HOSHIZAKI ICE MACHINE PERFORMED THE PREVENTIVE MAINTANCE ON THE ICE MACHINE
HEATCRAFT WALK IN COOLER NOT COOLING CURRENT TEMP IS NOW 50 DEGREES REPALCED THE THERMOSTAT
FRY MASTER FRYER PILOT LIGHT IS ON BUT DOSE NOT LIGHT FOUND THE WIRING HAD CAME LOOSE FROM THE ON/OFF TOGGLE SWITCH REWIRED AND THE UNIT IS WORKING
GOODMAN AIR CONDITIONER BAR AREA NOT COOLING FOUND THE BREAKER HAD BEEN TRIPPED
GOODMAN AIR CONDITIONER THE BAR AC NOT COOLING FOUND THE SCHRADER VAVLE LOOSE AND TIHGTEN THE VAVLE AND ADDED FREON
WHIRLPOOL REFRIGERATOR ICE MAKER DRIPPING WATER REPLACED THE INLET VALVE
WALK IN COOLER WALK IN COOLER TEMP IS RISING CLEANED THE CONDESER COILS
ADMIRAL WALK IN COOLER UNIT IS AT 50DEG/NOT COOLING CHARGED THEUNIT ALSO ADJUSTED THE TXV VALVE
ADMIRAL WALK IN COOLER NOT COOLING FOUND LEAK ON THE PRESSURE SWITCH
AC NOT COOLING EVAPORATOR HAD A LEAK ON THE HOT SIDE FIXED TH ELEAK AND UNIT IS WORKING FINE
HEATCRAFT WALK IN COOLER NOT COOLINGUNIT WAS LOW ON CHARGE ADDED REFRIGERATE
AMERICAN RANGE OVEN PILOT WILL NOT LIGHT CHANGED OUT PILOT ASSEMBLY
WALK IN COOLER NOT COOLING FOUND THE SYSTEM IS OVER CHARGED