Service call that the Heat was not keeping up to temperature on the Second Floor. Upon arrival found Second Floor Thermostat was set to 73, but the Temperature was actually at 69 Degrees. Tested both Zones Individually and separately and found that Zone 2 Powerhead had failed. Installed a new TACO Zone Valve Powerhead and put system back in operation. Allowed system to run and monitored to ensure the boiler was operating properly. Checked all Baseboards on the Second Floor and verified that they were getting hot. The Transformer and Relay Control is operating, but is starting to make an electrical buzzing noise. This occurs when the relay starts to wear and weaken. While it is operating properly now would recommend planning to replace this control in the future before any issues occur. Included estimate for the Control Center