Reclaimed and removed old equipment. Installed new leveled pad, disconnect, whip, and American standard condenser. Cut open wall between studs and Ran new lineset in 3 pieces, used zoom lock fittings and brazed in with nitrogen. Installed new American standard furnace. Placed new coil on top and brazed in with nitrogen. Pressure tested to 300 psi and evacuated down to 135 microns. Fabricated a plenum and sealed all ductwork. Reconnected gas and leak checked. Installed new ez trap and pump and ran condensate piping. Ran new vinyl to discharge. Reconnected Flue piping. Installed new receptacle and switch and reconnected electric. Wired in low volt. Tested all functions. Found stand pipe was clogged and blew out with gallon gun and tested. Performed combustion test and adjusted gas pressures. Charged unit to specifications. System running great at time of install.