Have any feedback for us? We'd love to hear it! Call us at (610) 595-9072 and let us know how we are doing.
Found collector box leaking and rusting away at furnace. Sealed up collector box with high temp silcone and performed precision heat tune up on Goodman gas furnace. Replaced 16x25x1 air filter. Checked all electrical conections and components. Blew out condensate drain. Adjusted gas pressures. Cleaned flame sensor, and performed combustion test. Gas furnace is working fine at time of service but has quite a bit of rust and corrosion from collector box leaking.