Support Existing Indoor coil and disconnect and remove old Furnace. Remove Auxiliary Drain Pan. Install new gas furnace in existing location in new Auxiliary Drain Pan on Furnace Feet. Complete connections of return and supply ducting. Build Custom Transition from Furnace to Indoor Coil as needed. Adapt 2" PVC venting for the Exhaust Piping, and reconnect gas line. Install new 4x4 Electrical Box with outlet and switch for unit and complete electrical connections. Install Wet Switch in Auxiliary Drain Pan and wire into system. Adapt Drain Piping to existing Condensation Pipe and ensure Condensation Drain line is clear. Install Honeywell T6 Pro Thermostat and setup Installer Programming. Setup programming on the Control Board for the system. Record all Equipment information to the System. Measure Gas Pressures and Combustion Levels. Complete Installation Checklist Form in system. Clean Work Area and review installation and Thermostat operation with the Homeowner