Have any feedback for us? We'd love to hear it! Call us at (610) 595-9072 and let us know how we are doing.
Checked no heat complaint, found no 120 volts to the furnace. All switches are closed and the breaker is on. Checked wiring, found a failed furnace service switch. Replaced service switch. Started gas furnace, checked air filter ok. Checked operation and temperature rise.