Have any feedback for us? We'd love to hear it! Call us at (610) 595-9072 and let us know how we are doing.
Performed Precision Air Conditioning Tune Up on system. Checked 14x25x1 Air Filter. Homeowner was concerned that the system did not seem to be blowing cold air and had previously frozen up. Temperature differential between the Supply and Return Air was 7 Degrees. Measured Refrigerant Levels and found system to be very low on refrigerant. Added 4lbs of R-22 Refrigerant to system, Charging to Target Superheat of 15 Degrees. Due to age of system, and the significant amount of Refrigerant that it has lost, recommend replacement of the Furnace and Air Conditioner. Joe will be in contact to go over replacement options and Pricing.