Have any feedback for us? We'd love to hear it! Call us at (610) 595-9072 and let us know how we are doing.
Performed Inspection/Tune Up on Attic AC system. The 20x30x1 Air Filter is dirty and needs to be replaced. Spoke with owner and he is going to purchase new filter and install. Tested components on Air Handler and Outdoor AC unit. Found Blower Motor Capacitor was testing below rating. Installed a new 10 Mfd Blower Motor Capacitor for system. Put system in operation and measured refrigerant charge on system. Rinsed outdoor coil with water due to having dirt buildup around the coil. Measured refrigerant charge on system. Reconnected 6†Flex Duct which supplies the Bathroom Register. Performed Heating Inspection/Tune Up on Gas Fired Boiler. Removed and cleaned Burner assemblies and inspected Heat Exchanger. Cleaned Ignitor and inspected components on Boiler. Put boiler in operation and performed Combustion Analysis and draft test. Zones are getting hot but Air is present in the lines. Would recommend purging both zones of Air and retesting system. Also would recommend Draining the Expan