Furnace was running when I arrived. Looked up code on Lennox gas furnace for 273 and found code to be last recycle due to flame failure. While I was in basement found furnace flames being blown around by high wind gusts down intake pipe , this was probibly what was making the error code happen. Also found flame sensor to be slightly dirty so also cleaned flame sensor. Cycled furnace for a little while any everything kept running , but did notice when hard wind gusts blew flames would move let home owner know all of this. Talked to homeowner about humidifier and she said she was not going to use it at this time. Went outside and found venting system to be half broken off. Talked to homeowner about repairing venting during tune up next week they agreed.