Replaced homeowner supplied watts water pressure reducing valve . Leak tested and pressure tested . Factory set at 55 lbs . Valve is working to factory standards. Removed old 50 gallon Pv water heater and replaced it with a new 50 gallon pv water heater . Reconnected cold supply and hot supply lines . Installed new tee and installed new expansion tank to tee . Reconnected gas line to new water heater . Leak tested gas line with bubbles. Reconnected exhaust pipe . Tested exhaust while water heater was running . Water heater was installed in a new pan with bricks . Water alarm was installed in pan . Relief pipe was installed. Before water heater was started up the pressure in the water heater was 55lbs . After the water heater heated up i took the pressure again and the pressure was 59lbs. After testing the water heater the water heater is running to standards with a 95 degree temperature.